• AKCP 60 ft 5 Input dry Contact Cable

An optional feature of the sensorProbe2DC is the ability to have up to 5 dry contact inputs per RJ45. This gives a total maximum possible inputs of 10 per sensorProbe2DC by utilizing both of the RJ45 sensor ports.

These dry-contact ports can be used to monitor any dry-contact inputs, just like the normal autosense dry-contact ports, but, these ports can only be set to operate in the input mode.These additional sensors are labeled as ports 3 to 12.

  • Optional 5 / max 10 dry contacts on sensorProbe2DC
  • Normally open/normally closed dry contact sensor
  • Input mode Only
  • Input voltage range 0-5 Volts

Specifications

Measurement Range : Alarm or Normal
Communications cable : RJ-45 jack to sensor using UTP Cat 5 wire
Sensor Type : Open / Closed contact switch
Input Voltage Range : 0 to 5 volts
Power Source : Powered by the sensorProbe. No additional power needed
Measurement Rate : Multiple readings every second
  Normal input voltage is settable under software
  Normally open, normally closed is settable under software
  Up to 5 dry contact inputs per RJ-45 making upto 10 Dry Contact Inputs in sensorProbe2 

Write a review

Please login or register to review

AKCP 60 ft 5 Input dry Contact Cable

  • $115.00



Are you a VAR / Distributor?
Up to 15% Commission.
No MOQs. No Signup Fees.

Tags: akcp, 60, ft, 5, input, dry, contact, cable



Featured Article

Portable Server Room Diagnostic Sensor Toolkit

Despite advances in CFD software and pre-deployment simulations of data center environments. The majority of server rooms, remote sites and data centers are not designed to handle ever increasing loads and the heat generated by that increased activity.

WIRELESS WORKFLOW enables early diagnostics of any server room or data center facility. Detecting problems arising from under or over cooling, hot air re-circulation in IT rack space and air delivery resulting in high or low air pressure in raised floors and dropped ceiling plenums.

Read the full article

Diagnosing server room temperature problems

Diagnose temperature differentials, pressure differentials and more...


AVTECH Room Alert 12E - Sensor Monitoring

Monitor temperature, humidity, power, room access and more...


AKCP SP2+ Temperature Monitoring

SP2+ monitors and logs temperature, humidity and more. SNMPv3 compliant, encrypted email and more...

Smart Cooling for Data Centers

Keeping temperatures in ASHRAE safe thermal envelopes.


AKCP SP2+ Temperature Sensor for Server Rooms

Front and rear thermal mapping for any server cabinet.


NTI Enviromux Micro-T SNMP Temperature Sensor

Monitor and manage server room environmental and security conditions over an IP network.


CTSI Limited - Complete Technology Systems Integration

At CTSI we've worked with some of the largest companies in the world, bringing our expertise to bear on many complex server room monitoring projects. Feel free to contact us today at sales@ctsilimited.com and make your project a success.