• AKCP Dry Contact Cable 60 ft

The Dry Contact sensor is a simple connection to burglar alarms, fire alarms or any application that requires monitoring by the sensorProbe. Dry contact sensors are user definable and can be used to detect many different inputs such as UPS status, security systems, air conditioning status.

These general purpose switches can be either input or output. When used as an output it can source up to 20 mAmps. You can select the output voltage by setting the Output Level to a Low or a High. When set to Low the pin will output 0 volts. When set as a High the pin will output 5 volts.

When used as an input a switch will retain any error condition until it is read via SNMP. Therefore if a switch encounters a critical condition at any time it must report that condition before it can return to a normal state.

Input pins can be used to detect whether or not an input switch is open or closed. In combination with external sensors, input pins can detect whether a door or window is open or closed, if there is a water incursion and many other conditions.

Specifications

Measurement Range : Alarm or Normal
Communications Cable : RJ-45 jack to sensor using UTP Cat 5 wire
Sensor Type : Open/closed contact switch
Measurement Rate : Multiple readings every second
Current Range : Can sink up to 20 mAmps
Power Source : powered by the sensorProbe. No additional power needed
  Input voltage range. 0 to 5 volts.
  Normal input voltage is settable under software
  Normally open, normally closed is settable under software
  Up to 2 dry contact sensors per sensorProbe2, 8 per sensorProbe8 and securityProbe
  Full autosense including disconnect alarm
 

Write a review

Please login or register to review

AKCP Dry Contact Cable 60 ft

  • $100.00



Are you a VAR / Distributor?
Up to 15% Commission.
No MOQs. No Signup Fees.

Tags: akcp, dry, contact, cable, 60, ft



Featured Article

Portable Server Room Diagnostic Sensor Toolkit

Despite advances in CFD software and pre-deployment simulations of data center environments. The majority of server rooms, remote sites and data centers are not designed to handle ever increasing loads and the heat generated by that increased activity.

WIRELESS WORKFLOW enables early diagnostics of any server room or data center facility. Detecting problems arising from under or over cooling, hot air re-circulation in IT rack space and air delivery resulting in high or low air pressure in raised floors and dropped ceiling plenums.

Read the full article

Diagnosing server room temperature problems

Diagnose temperature differentials, pressure differentials and more...


AVTECH Room Alert 12E - Sensor Monitoring

Monitor temperature, humidity, power, room access and more...


AKCP SP2+ Temperature Monitoring

SP2+ monitors and logs temperature, humidity and more. SNMPv3 compliant, encrypted email and more...

Smart Cooling for Data Centers

Keeping temperatures in ASHRAE safe thermal envelopes.


AKCP SP2+ Temperature Sensor for Server Rooms

Front and rear thermal mapping for any server cabinet.


NTI Enviromux Micro-T SNMP Temperature Sensor

Monitor and manage server room environmental and security conditions over an IP network.


CTSI Limited - Complete Technology Systems Integration

At CTSI we've worked with some of the largest companies in the world, bringing our expertise to bear on many complex server room monitoring projects. Feel free to contact us today at sales@ctsilimited.com and make your project a success.