33,000 BTU (9.7kW) In-Row Rack AC Unit
33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption. Precision cooling with inrush current protection and zero maintenance.


33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption

Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling adjustments--no more wasteful, noisy cycling between off and full blast

Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads

Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air stream--no floor drain, water collection tank, external condenser, refrigerant piping, duct work or plumbing required

Hardwire Input (User-supplied IEC 309 32-amp set, optional) - no electrician needed

200-240V AC Input, 50/60 Hz frequency compatibility

The harder your data center, network closet or server room works, the more it heats up, leading to inefficient operation, weakened performance and raised cooling costs. In fact, cooling can consume more than half of the power used by a high-density installation—start saving power and money with SRXCOOL33K today! The SRXCOOL33K provides 33,000 BTU of efficient, reliable cooling in a 42U rack form factor. It features cutting-edge components that limit inrush current and enable precision cooling adjustments to minimize power consumption, maximize cooling and improve your application efficiency.

By delivering cold air high in the cold aisle, the SRXCOOL33K promotes temperature uniformity from 1U to 42U, allowing your equipment to perform at its peak. Controlling the unit is simple with the intuitive LCD display, or control it from anywhere in the world with the included Modbus card or an optional network interface. With hardwire input(user supplied IEC 309 32-amp set, optional) and exhaust connection directly into the drop ceiling, you can install the unit with no electrician or contractor necessary, saving on up-front installation costs. Maintenance is no-hassle due to the self-contained design, which requires no water collection tank or extra plumbing, while RoHS compliance and eco-friendly R410a refrigerant means you’ll never have to worry about meeting environmental standards.

  • 33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption
  • Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling adjustments--no more wasteful, noisy cycling between off and full blast
  • Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads
  • Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air stream--no floor drain, water collection tank, external condenser, refrigerant piping, duct work or plumbing required
  • Convenient LCD control panel and network interface provide local and remote monitoring and control of temperature, humidity, fan speed, alarms and logging via front-panel buttons, SNMP, Web, telnet/SSH or Modbus
  • Row-based airflow path maximizes hot-aisle/cold-aisle efficiency and cooling predictability by supplying cold intake air high in the cold aisle and removing hot equipment exhaust air high in the hot aisle
  • Hardwire (User-supplied IEC 309 32-amp set, optional) - no electrician needed
  • RoHS compliance and R410A refrigerant meets environmental standards worldwide
  • 200-240V AC Input, 50/60 Hz frequency compatibility

Write a review

Please login or register to review

33,000 BTU (9.7kW) In-Row Rack AC Unit

  • Brand: TRIPPLITE
  • Product Code: TRIPPLITE SRXCOOL33K
  • Availability: In Stock Ships in 1-2 days
  • $11,475.00



Are you a VAR / Distributor?
Up to 15% Commission.
No MOQs. No Signup Fees.

Tags: SRXCOOL33K, Tripplite, Thermal Cooling, CRAC, Temperature Monitoring, Rack Efficiency



Featured Article

Portable Server Room Diagnostic Sensor Toolkit

Despite advances in CFD software and pre-deployment simulations of data center environments. The majority of server rooms, remote sites and data centers are not designed to handle ever increasing loads and the heat generated by that increased activity.

WIRELESS WORKFLOW enables early diagnostics of any server room or data center facility. Detecting problems arising from under or over cooling, hot air re-circulation in IT rack space and air delivery resulting in high or low air pressure in raised floors and dropped ceiling plenums.

Read the full article

Diagnosing server room temperature problems

Diagnose temperature differentials, pressure differentials and more...


AVTECH Room Alert 12E - Sensor Monitoring

Monitor temperature, humidity, power, room access and more...


AKCP SP2+ Temperature Monitoring

SP2+ monitors and logs temperature, humidity and more. SNMPv3 compliant, encrypted email and more...

Smart Cooling for Data Centers

Keeping temperatures in ASHRAE safe thermal envelopes.


AKCP SP2+ Temperature Sensor for Server Rooms

Front and rear thermal mapping for any server cabinet.


NTI Enviromux Micro-T SNMP Temperature Sensor

Monitor and manage server room environmental and security conditions over an IP network.


CTSI Limited - Complete Technology Systems Integration

At CTSI we've worked with some of the largest companies in the world, bringing our expertise to bear on many complex server room monitoring projects. Feel free to contact us today at sales@ctsilimited.com and make your project a success.